> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/microarray/decode-file-client-software/microarray-decode-file-client-software-reference_material-list/000001523.md). Agents can also search and read this documentation through its [MCP server](https://knowledge.illumina.com/~gitbook/mcp).

# Tips and tricks for downloading DMAPs using the Decode File Client

**DMAPs are:**

* The map files that provide the location of probes on a BeadChip
* Unique to each BeadChip, and are required to scan BeadChips
* Downloaded using the Decode File Client software
* Available for download 24 to 48 hours after the BeadChips are shipped
* Available for download until two years after the date of manufacture

**Install the Decode File Client to download DMAPs:**

* Click [here](https://support.illumina.com/array/array_software/decode_file_client/downloads.html) to download the latest version of Decode File Client Installer and Release Notes.
  * **Note**: As of 20-OCT-2026, the latest version is Decode File Client v3.0.5.
* Computing requirements are provided on page 4 of the [Decode File Client Software Guide](http://support.illumina.com/downloads/dmap_decode_file_client_user_guide_\(11337856_c\).html).
* Make sure that both outgoing and incoming network access is allowed by your institution. The Decode File Client has no firewall or security restrictions.

**Download the DMAPs:**

1. Log in to the Decode File Client using the **Access by BeadChip** option with your MyIllumina user ID and password.
   * The user ID (email) and password are case-sensitive. The user ID must match the email address in your MyIllumina account (visible under MyIllumina Settings > Profile tab).
   * To create a MyIllumina account, navigate to the [MyIllumina Sign In page](https://login.illumina.com/) and select **Sign up**. Make sure to accept all end-user license agreements.
2. After logging in, enter two of the following pieces of information, one in the Primary Field and one in the Verification Field: (**Note**:The information entered in the Primary Field dictates the search results. Entering the barcodes or Box IDs in the Primary Field limits the results to those items, whereas, entering the Purchase Order or Sales Order in the Primary Field will give all items within that order.)
3. 1. List of BeadChip Barcodes - found on the BeadChip foil pack
   2. List of BeadChip Box IDs (CHP-) - found on the packing slip
   3. Purchase Order (PO) number - found on the packing slip
   4. Illumina Sales Order number (exclude the letters that follow the numbers) - found on the packing slip
4. Select **Find**. A list of available BeadChip barcodes are displayed. Select the DMAPs to download.
5. Specify the destination folder to which to save the DMAPs.
6. Select **Start Download**.

**Best practices:**

* Prior to starting the Infinium assay, download DMAPs to confirm availability. For more information, refer to [DMAP File Availability and Retention Policy for Infinium Arrays](https://knowledge.illumina.com/microarray/general/microarray-general-reference_material-list/000005602.md).
* Make sure that the two types of information entered in the Primary and Verification fields are associated (eg, the correct Box ID for a barcode, or the correct Sales Order number for Box ID).
* Make sure the download location (computer or network) has sufficient disk space.
* For large orders of BeadChips or to improve download speed:
  * Download in smaller batches using the Box IDs or barcodes in the Primary Field, rather than the Sales Order number or Purchase Order number.
  * Download to the local drive instead of a network drive.

For additional information, refer to the [Decode File Client Software Guide](http://support.illumina.com/downloads/dmap_decode_file_client_user_guide_\(11337856_c\).html) or contact Illumina Technical Support at <techsupport@illumina.com>.

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                   |
| :---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #1523), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000001523%20-%20Microarray%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://knowledge.illumina.com/microarray/decode-file-client-software/microarray-decode-file-client-software-reference_material-list/000001523.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.