> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/library-preparation/rna-library-prep/library-preparation-rna-library-prep-faq-list/000008542.md).

# TruSeq Small RNA alternative T4 RNA Ligase 2, Deletion Mutant supplier

The [TruSeq Small RNA reference guide](https://support.illumina.com/downloads/truseq-small-rna-library-prep-guide-15004197.html) lists T4 RNA Ligase 2, Deletion Mutant #LR2D1132K and LR2D11310K as user-supplied consumables. However, Lucigen has discontinued this product.

Illumina has identified New England Biolab T4 RNA Ligase 2, truncated (Catalog #M0242) as a suitable alternative to the Lucigen T4 RNA Ligase, Deletion Mutant enzyme. NEB M0242 is now recommended for use in the TruSeq Small RNA assay. This enzyme should be used as a 1:1 substitution without any protocol changes.

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                              |
| :--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #8542), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000008542%20-%20Library%20Preparation%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://knowledge.illumina.com/library-preparation/rna-library-prep/library-preparation-rna-library-prep-faq-list/000008542.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.