> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/microarray/general/microarray-general-troubleshooting-list/000006290.md).

# What is the correct format for DRAGEN Array IDAT CSV Sample Sheet?

When using DRAGEN Array (Cloud or Local) analysis, providing a sample sheet is optional. A sample sheet enables users to analyze samples located in different directories and select specific samples for analysis rather than processing every sample on a BeadChip.

The DRAGEN Array IDAT CSV Sample Sheet is a CSV-formatted input file that utilizes a couple required fields for sample lookup. These fields associate a sample identifier with the corresponding Sentrix Barcode and position on the BeadChip.

For DRAGEN Array Local workflows, the required lookup fields are:

SentrixBarcode\_A\*\*:\*\* BeadChip barcode

SentrixPosition\_A\*\*:\*\* BeadChip position

![](https://761066130-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGM9W2DuBTgEXv1ClCm8H%2Fuploads%2Fgit-blob-5496540a9c81b3177e281682716346ba6663584f%2Fimage1.png?alt=media)

**Figure 1.** Example of a DRAGEN Array Local IDAT CSV Sample Sheet.

For DRAGEN Array Cloud workflows, the required lookup fields are:

beadChipName\*\*:\*\* BeadChip barcode

sampleSectionName

![](https://761066130-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGM9W2DuBTgEXv1ClCm8H%2Fuploads%2Fgit-blob-2b03aa59f5cf36723d1dd11313e01971c5cb0ae9%2Fimage2.png?alt=media)

**Figure 2.** Example of a DRAGEN Array Cloud IDAT CSV Sample Sheet.

The DRAGEN Array CSV Sample Sheet format differs from the GenomeStudio CSV Sample Sheet format. It uses a simplified structure and includes only the information required for DRAGEN Array analysis workflows. In contrast, the GenomeStudio sample sheet may contain additional columns and data fields that are intended for use with GenomeStudio software.

Although the two sample sheet formats differ, the recommendations for formatting 12-digit BeadChip barcodes apply to both DRAGEN Array and GenomeStudio sample sheets.

**Note:** Beginning with DRAGEN Array v1.3, backward compatibility with the GenomeStudio CSV Sample Sheet format was introduced for DRAGEN Array Local CLI Analysis workflows. This compatibility does not apply to all DRAGEN Array workflows.

**References:**

* [Is a sample sheet required to run DRAGEN Array?](https://knowledge.illumina.com/microarray/general/microarray-general-faq-list/000009345.md)
* [How to avoid sample sheet formatting errors when creating a GenomeStudio project](https://knowledge.illumina.com/microarray/general/microarray-general-reference_material-list/000001422.md)
* [Troubleshooting DRAGEN Array Cloud error Sample sheet missing required columns](https://knowledge.illumina.com/microarray/general/microarray-general-troubleshooting-list/000010004.md))
* [DRAGEN Array Sample Sheet Templates](https://support.illumina.com/downloads/dragen-array-sample-sheet-templates.html)
* [DRAGEN Array User Guide](https://help.dragenarray.illumina.com/) under section [Input Files](https://help.dragenarray.illumina.com/product-guides/input-files)
* [How to format file path for DRAGEN Array IDAT sample sheet and GTC sample sheet for Windows OS](https://github.com/illumina-swi/illumina-knowledge/tree/master/docs/Microarray/General/FAQ/000008510.md)

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                   |
| :---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #6290), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000006290%20-%20Microarray%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://knowledge.illumina.com/microarray/general/microarray-general-troubleshooting-list/000006290.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.