> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/library-preparation/rna-library-prep/library-preparation-rna-library-prep-reference_material-list/000002096.md).

# Species compatibility table for Ribo-Zero Plant

TruSeq Stranded Total RNA with Ribo-Zero Plant has been laboratory tested with Arabidopsis, corn, maize, rice, soybean, and wheat samples, but may be applicable to a variety of species.

The following table lists organisms which have been laboratory tested and are fully supported by Illumina, tested *in silico*, or reported to work by non-Illumina labs. Illumina cannot guarantee rRNA removal based on *in silico* or non-Illumina lab reported results.

This table can also be found on the [Stranded Total RNA Species Compatibility Tables webpage](https://www.illumina.com/products/selection-tools/truseq-total-rna-species-compatibility.html).

| Organism                                  | Laboratory Tested | In silico Tested | Customer Reported | Comments                                                                                                                                          |
| ----------------------------------------- | ----------------- | ---------------- | ----------------- | ------------------------------------------------------------------------------------------------------------------------------------------------- |
| Arabidopsis                               | yes               |                  | yes               | Compatible with leaves, seeds and roots.                                                                                                          |
| Chickpea (Cicer arietinum)                |                   | yes              |                   | Removes 4.5S, 16S, 23S chloroplast rRNA and 18S cytoplasmic rRNA. Will not remove 5S chloroplast and 5S cytoplasmic rRNA. Other rRNAs not tested. |
| Corn                                      | yes               |                  | yes               | Compatible with leaves, seeds and roots.                                                                                                          |
| Cotton                                    |                   | yes              |                   |                                                                                                                                                   |
| Eukaryotic green algae (Chlamydomonas)    |                   | yes              |                   | Use highest quality RNA possible.                                                                                                                 |
| Grape vine                                |                   |                  | yes               |                                                                                                                                                   |
| Japanese honeysuckle (Lonicera japonica)  |                   |                  | yes               |                                                                                                                                                   |
| Maize                                     | yes               |                  |                   | Compatible with leaves, seeds and roots.                                                                                                          |
| Mirror bush (Coprosma repens)             |                   | yes              |                   |                                                                                                                                                   |
| Moss (Physcomitrella)                     |                   |                  | yes               |                                                                                                                                                   |
| Prorocentrum minimum                      |                   | yes              |                   | Removes 18S and 28S rRNA. Other rRNAs not tested.                                                                                                 |
| Rice                                      | yes               |                  | yes               | Compatible with leaves, seeds and roots.                                                                                                          |
| Soybean                                   | yes               |                  |                   | Compatible with leaves, seeds and roots.                                                                                                          |
| Tomato (Solanum lycopersicum)             |                   |                  | yes               |                                                                                                                                                   |
| Vietnamese coriander (Persicaria odorata) |                   |                  | yes               |                                                                                                                                                   |
| Water clover (Marsilea vistita)           |                   | yes              |                   |                                                                                                                                                   |
| Welsh onion                               |                   | yes              |                   | Use highest quality RNA possible.                                                                                                                 |
| Wheat                                     | yes               |                  |                   | Compatible with leaves, seeds and roots.                                                                                                          |

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                              |
| :--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #2096), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000002096%20-%20Library%20Preparation%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://knowledge.illumina.com/library-preparation/rna-library-prep/library-preparation-rna-library-prep-reference_material-list/000002096.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
