> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/instrumentation/general/instrumentation-general-reference_material-list/000001508.md). Agents can also search and read this documentation through its [MCP server](https://knowledge.illumina.com/~gitbook/mcp).

# Approximate sizes of sequencing run output folders

**Background**

The run folder sizes listed in this article are only an approximation based on dual-indexed runs with optimal cluster densities for each platform. For runs on nonpatterned flow cells, the size approximation is based on runs with clusters passing filter greater than 80%.

The actual size will vary depending on the raw cluster density and the number of clusters passing filter for each run.

Additional run folder size considerations:

* iSeq 100, MiniSeq and NextSeq 500/550 (NextSeq Control Software v4.0 and higher) folder sizes include FASTQ files generated by the Local Run Manager FASTQ workflow.
* MiSeq folder sizes include FASTQ files generated by either the MiSeq Reporter FASTQ workflow or the Local Run Manager FASTQ workflow (MiSeq Control Software 3.1 and higher).
* NextSeq 1000/2000 folder sizes include local analysis output, which can add another 25-120+ GB depending on workflow.
* NovaSeq 6000 folders do not include FASTQ files as part of the total output folder size as no onboard analysis is available for this platform.
* The output folder size in the tables below is reported in Gigabytes (GB), except for the NovaSeq X which is reported in Terabytes (TB).

Illumina recommends storing the output folder for iSeq 100, NextSeq 500/550, and NextSeq 1000/2000 runs on a network location. NovaSeq 6000 and NovaSeq X Series Control Software requires storing the output folder on a network location.

**iSeq 100**

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 2 x 150     | 1.5 - 2.5                |

**MiniSeq**

Mid Output

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 2 x 150     | 2.3 - 2.6                |

High Output

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 2 x 150     | 7.0 - 8.0                |
| 2 x 75      | 6.0 - 8.0                |
| 1 x 75      | 2.0 - 4.0                |

Rapid

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 1 x 100     | 2                        |

**MiSeq**

v3 chemistry

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 2 x 300     | 22 - 26                  |
| 2 x 75      | 19 - 22                  |

v2 chemistry

| Read Length | Reagent Kit Configuration | Output Folder Size in GB |
| ----------- | ------------------------- | ------------------------ |
| 2 x 250     | Standard                  | 22 - 24                  |
| 2 x 250     | Nano                      | 1.6 - 1.8                |
| 2 x 150     | Standard                  | 16 - 18                  |
| 2 x 150     | Micro                     | 3.0 - 5.0                |
| 2 x 150     | Nano                      | 0.8 - 1.2                |
| 2 x 25      | Standard                  | 14 - 16                  |

**MiSeq i100 Series**

See Knowledge Article [Estimating Disk Space Utilization on the MiSeq i100 Series](https://knowledge.illumina.com/instrumentation/miseq-i100-series/instrumentation-miseq-i100-series-reference_material-list/000009356.md)

**NextSeq 500/550**

Mid Output

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 2 x 150     | 62 - 66                  |
| 2 x 75      | 39 - 46                  |

High Output

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 2 x 150     | 160 - 170                |
| 2 x 75      | 92 - 97                  |
| 1 x 75      | 50 - 78                  |

**NextSeq 1000/2000 (Standard and XLEAP runs are expected to have similar sizes)**

P1

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 2 x 300     | 85-95                    |
| 2 x 150     | 50 - 55                  |
| 2 x 101     | 40 - 45                  |
| 2 x 75      | 35 - 40                  |

P2

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 2 x 300     | 140-160                  |
| 2 x 150     | 89 - 99                  |
| 2 x 101     | 65 - 66                  |
| 2 x 75      | 44 - 55                  |

P3

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 2 x 150     | 165 - 170                |
| 2 x 101     | 103 - 126                |

P4 (XLEAP Only)

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 2 x 150     | 170 - 180                |
| 2 x 100     | 100 - 130                |
| 2 x 50      | 70 - 80                  |
| 1 x 50      | 40 - 50                  |

**NovaSeq 6000**

SP

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 1 x 36      | 20                       |
| 2 x 150     | 185                      |
| 2 x 250     | 400                      |

S1

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 2 x 150     | 370                      |

S2

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 2 x 150     | 730                      |

S4

| Read Length | Output Folder Size in GB |
| ----------- | ------------------------ |
| 1 x 36      | 240                      |
| 2 x 150     | 2190                     |

**NovaSeq X Series**

Values listed below are PER FLOW cell in Terabytes (TB).

1.5B

| Read Length | cBCL Only in TB | BCL Convert (GZIP) in TB | BCL Convert (ORA) in TB |
| ----------- | --------------- | ------------------------ | ----------------------- |
| 2 x 50      | 0.054 - 0.091   | 0.132 - 0.221            | 0.086 - 0.143           |
| 2 x 100     | 0.106 - 0.181   | 0.265 - 0.442            | 0.173 - 0.286           |
| 2 x 150     | 0.163 - 0.272   | 0.397- 0.662             | 0.259 - 0.429           |

10B

| Read Length | cBCL Only in TB | BCL Convert (GZIP) in TB | BCL Convert (ORA) in TB |
| ----------- | --------------- | ------------------------ | ----------------------- |
| 2 x 50      | 0.34 - 0.57     | 0.83 - 1.38              | 0.54 - 0.89             |
| 2 x 100     | 0.68 - 1.13     | 1.65 - 2.76              | 1.08 - 1.79             |
| 2 x 150     | 1.02 - 1.70     | 2.48 - 4.14              | 1.62 - 2.68             |

25B

| Read Length | cBCL Only in TB | BCL Convert (GZIP) in TB | BCL Convert (ORA) in TB |
| ----------- | --------------- | ------------------------ | ----------------------- |
| 2 x 50      | 0.85 - 1.42     | 2.07 - 3.45              | 1.35 - 2.23             |
| 2 x 100     | 1.70 - 2.83     | 4.13 - 6.90              | 2.70 - 4.47             |
| 2 x 150     | 2.55 - 4.25     | 6.200 - 10.35            | 4.05 - 6.70             |

DRAGEN Analysis files can ADD the following additional data in terabytes (TB) to the expected Output folder size based on Analysis options selected. Approximate file sizes are based on a single flow cell, 2x150 cycle sequencing run.

| Flow Cell Type | BAM (TB) | CRAM (TB) | GVCF+VCF (TB) |
| -------------- | -------- | --------- | ------------- |
| 1.5B           | 0.4      | 0.1       | <0.1          |
| 10B            | 2.5      | 1.0       | 0.2           |
| 25B            | 6.3      | 2.5       | 0.5           |

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                        |
| :--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #1508), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000001508%20-%20Instrumentation%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://knowledge.illumina.com/instrumentation/general/instrumentation-general-reference_material-list/000001508.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.