> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/instrumentation/general/instrumentation-general-reference_material-list/000001544.md). Agents can also search and read this documentation through its [MCP server](https://knowledge.illumina.com/~gitbook/mcp).

# What is the final formamide concentration in the waste solution of Illumina sequencing systems?

This article provides information to help calculate the final concentration of formamide in the waste solution of Illumina sequencing runs.

Formamide concentration in the final waste solution of each run varies depending on the instrument and the length of the run. To determine the concentration of formamide, measure the final waste volume and perform the appropriate calculations as explained in the following table.

![](https://761066130-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGM9W2DuBTgEXv1ClCm8H%2Fuploads%2Fgit-blob-52c846f902c0e18d2170be7a9efe2a30fa50ec59%2Fimage1.jpg?alt=media)

\*The iSeq 100 reagent cartridge is solid waste as it is not intended to be opened.

\*\*Without purge, formamide concentration can range from 0.35 - 1.5% depending on run cycles.

**NovaSeq X/X Plus**\
The formamide concentration in the waste solution for a NovaSeq X/X Plus run depends on the number of insert and index reads that were performed.

![](https://761066130-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGM9W2DuBTgEXv1ClCm8H%2Fuploads%2Fgit-blob-d3537ebec3ca10e9bd5b44eec4f226aa42ffb10d%2Fimage2.png?alt=media)

For additional information pertaining to NovaSeq X/X Plus waste, see [Handling and Disposal Recommendations for Used Reagents on the NovaSeq X Series](https://knowledge.illumina.com/instrumentation/novaseq-x-x-plus/instrumentation-novaseq-x-x-plus-faq-list/000008392.md)

**MiSeq i100 / i100 Plus**

The cartridge is formamide-free and can be discarded similarly to PCR product waste.

Safely dispose of formamide with appropriate Personal Protective Equipment. Regulations for the proper disposal of formamide and other hazardous components in the waste vary by region. Contact the local Environmental Health and Safety (EH\&S) office for the definition of hazardous materials and how to dispose of containers and unused contents in accordance with the governmental and regional safety standards. See the [Safety Data Sheets (SDS)](https://support.illumina.com/sds.html) on the Illumina support page for more information about chemicals found in Illumina reagents.

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                        |
| :--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #1544), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000001544%20-%20Instrumentation%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://knowledge.illumina.com/instrumentation/general/instrumentation-general-reference_material-list/000001544.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.