> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/microarray/general/microarray-general-faq-list/000008510.md).

# How to format file path for DRAGEN Array IDAT sample sheet and GTC sample sheet for Windows OS

### **IDAT Sample Sheet**

#### **Local Analysis:** IDAT sample sheet can be a CSV or JSON formatted file with direct paths to sample IDAT files to enable analysis of samples from different directories.

**CSV format for Linux:**

```
Green IDAT Path,Red IDAT Path  
/path/to/sample1_Grn.idat,/path/to/sample1_Red.idat  
/path/to/sample2_Grn.idat,/path/to/sample2_Red.idat  
/path/to/sample3_Grn.idat,/path/to/sample3_Red.idat  
```

**CSV format for Windows (use double backslash):**

```
Green IDAT Path,Red IDAT Path  
\\path\\to\\sample1_Grn.idat,\\path\\to\\sample1_Red.idat  
\\path\\to\\sample2_Grn.idat,\\path\\to\\sample2_Red.idat  
\\path\\to\\sample3_Grn.idat,\\path\\to\\sample3_Red.idat  
```

**JSON format for Linux:**

```
[  
{  
"Green IDAT Path": "/path/to/sample1_Grn.idat",  
"Red IDAT Path": "/path/to/sample1_Red.idat"  
},  
{  
"Green IDAT Path: "/path/to/sample2_Grn.idat",  
"Red IDAT Path": "/path/to/sample2_Red.idat"  
},  
{  
"Green IDAT Path": "/path/to/sample3_Grn.idat",  
"Red IDAT Path": "/path/to/sample3_Red.idat"  
},  
]  
```

**JSON format for Windows (use double backslash):**

```
[  
{  
"Green IDAT Path": "\\path\\to\\sample1_Grn.idat",  
"Red IDAT Path": "\\path\\to\\sample1_Red.idat"  
},  
{  
"Green IDAT Path: "\\path\\to\\sample2_Grn.idat",  
"Red IDAT Path": "\\path\\to\\sample2_Red.idat"  
},  
{  
"Green IDAT Path": "\\path\\to\\sample3_Grn.idat",  
"Red IDAT Path": "\\path\\to\\sample3_Red.idat"  
},  
]  
```

####

#### **Cloud analysis:** The IDAT sample sheet can be a CSV formatted file.

```
beadChipName,sampleSectionName  
204753010023,R01C01  
204753010023,R02C01  
204753010024,R01C01  
204753010024,R02C01  
```

### **GTC Sample Sheet**

#### **Local Analysis:** GTC sample sheet can be a CSV or JSON formatted file with direct paths to sample GTC files to enable analysis of samples from different directories.

**CSV format for Linux:**

```
GTC Path  
/path/to/sample1.gtc  
/path/to/sample2.gtc  
/path/to/sample3.gtc  
```

**CSV format for Windows (use double backslash):**

```
GTC Path  
\\path\\to\\sample1.gtc  
\\path\\to\\sample2.gtc  
\\path\\to\\sample3.gtc  
```

**JSON format for Linux:**

```
[  
{  
"GTC Path": "/path/to/sample1.gtc"  
},  
{  
"GTC Path": "/path/to/sample2.gtc"  
},  
{  
"GTC Path": "/path/to/sample3.gtc"  
}  
]  
```

**JSON format for Windows (use double backslash):**

```
[  
{  
"GTC Path": "\\path\\to\\sample1.gtc"  
},  
{  
"GTC Path": "\\path\\to\\sample2.gtc"  
},  
{  
"GTC Path": "\\path\\to\\sample3.gtc"  
}  
]  
```

For more information, refer to the following:

* [DRAGEN Array User Guide](https://help.dragenarray.illumina.com/overview/readme)
* [DRAGEN Array Secondary Analysis Software Downloads](https://support.illumina.com/array/array_software/dragen-array-secondary-analysis/downloads.html) under section 'DRAGEN Array Sample Sheet Templates'

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                   |
| :---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #8510), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000008510%20-%20Microarray%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://knowledge.illumina.com/microarray/general/microarray-general-faq-list/000008510.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.