# Troubleshooting

Instrumentation > MiniSeq > Troubleshooting

* [Blank BaseSpace login screen during run setup on MiniSeq Control Software v2](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000003273)
* [Chemistry and Imaging on MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000005628)
* [Import run option is not available following Local Run Manager Upgrade to 1.3.1 on MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000001202)
* [MiniSeq Control Software v2.0 not able to display BaseSpace page on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000003272)
* [MiniSeq Control Software v2.0 “Invalid Role” error with Local Run Manager v2.4.1](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000002304)
* [MiniSeq run display anomaly in Sequencing Analysis Viewer with Mid Output Flow Cells](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000001201)
* [Operational Qualifications Results upload prompt at end of run on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000002236)
* [Pre Run Check Troubleshooting on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000001214)
* [Pre run check stalls on flow cell registration after installation of MiniSeq Control Software v2.0](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000002237)
* [Single Read option not available with Resequencing Analysis for the TruSeq HT kit on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000001216)
* [The optimal cluster density and PhiX loading concentration for MiniSeq runs](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000002008)
* [Troubleshooting "Ebox0 Fan is not operating as expected" warnings on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000007359)
* [Troubleshooting "Error in Fluidics, LanePump" error on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000007120)
* [Troubleshooting "RunCopyService executable does not exist" error in MiniSeq Control Software 1.3.1](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000001218)
* [Troubleshooting "Unable to create Output folder. MiniSeq does not have access to…" on MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000001210)
* [Troubleshooting "Y Stage Initialization Error Operation home failed..." errors on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000001815)
* [Troubleshooting Computer reboot hangs with Illumina logo splash screen on MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000001814)
* [Troubleshooting Duplicate analysis folders created for runs with successful LRM analyses on MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000002623)
* [Troubleshooting MiniSeq Z stages are not ready initialization error](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000006299)
* [Troubleshooting MiniSeq fails optical and stage tests "While measuring LED power"/"Failed XY Stage"](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000001809)
* [Troubleshooting RFID block can not be written (due to lock status) Error on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000008099)
* [Troubleshooting Timeout waiting 60000 ms within event EventToBlockingConverter error on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000002046)
* [Troubleshooting Windows 10 needs to be activated error on the MiniSeq.](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000005678)
* [Troubleshooting a "Syringe Overload" error on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000007953)
* [Troubleshooting camera, cluster, and focus errors at cycle 1 on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000001198)
* [Troubleshooting socket errors on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000001219)
* [Troubleshooting validation errors displaying when opening "module create run" page on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000001221)
* [Unable to pass pre run checks with Imaging Limits test on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000002061)
* [Wash Error "Binary Part number revision .. byte1 is invalid" on the MiniSeq](https://knowledge.illumina.com/instrumentation/miniseq/instrumentation-miniseq-troubleshooting-list/000001222)