Troubleshooting DRAGEN installation failed due to lack of disk space in root file system
Sometimes the error below can occur during installation of DRAGEN software:
Need at least X MB in /, have Y MBNot enough free space in /, need at least Z MB moreNot enough space to install
The error indicates a disk space issue on the root file system.
A user can try using the --target option:
sudo /staging/dragen-version.run --target /staging
That will tell it to extract its temporary data to /staging (rather than /tmp) and it may bypass the disk space issue. If that does not solve the issue, likely the only solution is to actually free space on the root file system.
DRAGEN versions 4.3 or higher can be co-installed on a DRAGEN server. If there are many versions of DRAGEN installed, uninstalling a specific version could be used to reduce storage on the root file system.
For any feedback or questions regarding this article (Illumina Knowledge Article #8926), contact Illumina Technical Support techsupport@illumina.com.