> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/software/general/software-general-reference_material-list/000009925.md).

# How to build a custom reference hashtable for BaseSpace DRAGEN Single Cell RNA analysis

DRAGEN analyses use a hashtable reference to map a sequencing reads to a reference genome. These hashtables are a custom binary format of the reference genome required by DRAGEN. When using the DRAGEN Single Cell RNA app in BaseSpace, there are several default references provided, depending on the version of the app used:

* DRAGEN Single Cell RNA v4.4.4: hg19 (linear and pangenome), hg38 (linear and pangenome), hs37d5 (linear and pangenome), hg38-mm39, mm10, mm39, rn6
* DRAGEN Single Cell RNA v4.4.6: hg19 (linear and pangenome), hg38 (linear and pangenome), hs37d5 (linear and pangenome), hg38-mm39, mm10, mm39, rn6
* DRAGEN Single Cell RNA v4.4.2: (this version has been deprecated) hg19 (linear and pangenome), hg38 (linear and pangenome), hs37d5 (linear and pangenome), mm10, rn6

If interested in using a non-default or custom reference with the DRAGEN Single Cell RNA app, the DRAGEN Reference Builder app in BaseSpace Sequence Hub can be used to generate a hashtable reference from input FASTA files of the desired reference. The hashtable version must match the one expected by the DRAGEN Single Cell RNA Analysis pipeline. Refer to the table below for compatibility.

|                               | Analysis Setup    | Hashtable Version | Hash Table Application             |
| ----------------------------- | ----------------- | ----------------- | ---------------------------------- |
| DRAGEN Single Cell RNA v4.4.4 | Manual App Launch | 11                | DRAGEN Reference Builder v4.4.4001 |
| DRAGEN Single Cell RNA v4.4.6 | Manual App Launch | 11                | DRAGEN Reference Builder v4.4.6002 |

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                 |
| :-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #9925), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000009925%20-%20Software%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://knowledge.illumina.com/software/general/software-general-reference_material-list/000009925.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
