> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/software/general/software-general-faq-list/000002240.md).

# MiSeq Reporter common questions

**Which browsers are supported for MiSeq Reporter?**

MiSeq Reporter can be viewed with the following web browsers: Firefox 13.0.1+, Internet Explorer (IE) 11+, and Safari 5.1.7+.

Silverlight support has been discontinued for these browsers (Firefox 13.0.1+ and Safari 5.1.7+), so without Internet Explorer, an upgrade to a control software with Local Run Manager (LRM) is required.

**How to verify that MiSeq Reporter has completed its analysis?**

When MiSeq Reporter analysis is finished, a checkmark appears in the State column of the Analyses tab and the CompletedJobInfo.xml file is written to the root level of the analysis folder.

**Does the Library QC workflow in MiSeq Reporter perform alignment?**

Yes, alignment is performed in the Library QC workflow; however, it is performed using a faster and less sensitive setting, which provides a much faster turnaround time. Variant calling is not performed for this workflow.

**How to access MiSeq Reporter?**

The MiSeq Reporter interface can only be viewed through a web browser. To view the MiSeq Reporter interface during analysis, open any web browser on a computer with access to the same network as the MiSeq system. Connect to the HTTP service on port 8042 using one of the following methods:

![](https://761066130-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGM9W2DuBTgEXv1ClCm8H%2Fuploads%2Fgit-blob-aa772a5e56239f1fc75529f2f7e9791a198c1870%2Fimage1.png?alt=media\&token=cd50f621-8075-4c0b-9d50-b2bb7d878e13)

**MiSeq Reporter indicates a sample numbered 0. What is sample 0?**

Sample 0 is not designated in the sample sheet. Reads that were not successfully assigned to any of the samples from the sample sheet are written to an Undetermined FASTQ file for sample number 0, and excluded from downstream analysis.

**Can secondary analysis run on the MiSeq while a sequencing run is in progress?**

If a new sequencing run is started on the MiSeq before the secondary analysis of a previous run is complete, the secondary analysis will be stopped automatically. MiSeq computing resources are dedicated to either sequencing or analysis, and the system is designed in such a way that a sequencing command overrides an analysis command. Secondary analysis can later be requeued from the MiSeq Reporter Analyses tab.

**How to requeue a run for analysis in MiSeq Reporter?**

MiSeq Reporter must have access to the repository, which is the location of the folder containing data for analysis. Set this location in the settings window on the MiSeq Reporter main screen. When MiSeq Reporter has access to the repository, runs appear in the Analyses tab in MiSeq Reporter. Select the Requeue checkbox next to the run to be analyzed, and then select Requeue to start analysis.

**How long does it take for MiSeq secondary analysis to complete?**

For a 2 x 250 bp run, the analysis takes about 3 hours. This timing is dependent on running the latest PC RAM configuration on the MiSeq. This also depends on the genome size for resequencing. If analysis is taking longer than two hours, consider mapping to a more appropriate reference, or perform analysis offline by installing MiSeq Reporter on another computer.

If an alignment is performed against the whole genome, then the analysis time will be significantly longer than two hours. Also, bioinformatics analysis for metagenomics may take as long as 12 hours.

**Can secondary analysis by MiSeq Reporter be delayed after a sequencing run completes?**

No, the secondary analysis cannot be delayed automatically. Secondary analysis will automatically stop if run set up is performed on the instrument.

**Is the version of MiSeq Reporter software used for analysis recorded in the run folder?**

The MiSeq Reporter software version can be found in the following files located at the root level of the run folder: the log file AnalysisLog.txt, the CompletedJobInfo.xml file, and the workflow-specific results file (eg, ResequencingRunStatistics.xml).

**In what format does MiSeq Reporter output aligned data?**

MiSeq Reporter outputs aligned data in the BAM file format.

**Does MiSeq Reporter recognize \*.fasta or \*.fa?**

Yes, MiSeq Reporter recognizes both extensions.

**Which genomes and databases are used for alignment and variant detection?**

The MiSeq comes with pre-installed databases, which include miRbase, dbSNP, and refGene. Also included are eight genomes: Arabidopsis thaliana, cow (Bos taurus), E. coli strain DH10b, hg19, mouse (Mus musculus), rat (Rattus norvegicus), yeast (Saccharomyces cerevisiae), and Staphylococcus aureus. You can also upload your own references in fasta format (\*.fasta or \*.fa).

**Can the MiSeq generate FASTQ files?**

FASTQ files are generated during secondary analysis by MiSeq Reporter for most analysis workflows. To generate only FASTQ files, specify the GenerateFASTQ workflow in the sample sheet, which generates FASTQ files and then exits secondary analysis.

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                 |
| :-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #2240), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000002240%20-%20Software%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://knowledge.illumina.com/software/general/software-general-faq-list/000002240.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.