How to build a Custom Reference Hashtable for BaseSpace DRAGEN Single Cell RNA Application

DRAGEN uses hashtable references to map sequence reads to a reference genome. It generates hashtables from FASTA files, which serve as input. These hashtables are a custom binary format of the reference genome required by DRAGEN. The hashtable version must match the one expected by the DRAGEN Single Cell RNA Analysis pipeline.

Refer to the table below for compatibility:

Analysis Setup

Hashtable Version

Hash Table Application

DRAGEN Single Cell 4.4.2

Run Planning

10

Reference Builder (Instruments) v3.0.0

DRAGEN Single Cell 4.4.2

Manual App Launch

10

DRAGEN Reference Builder 4.3.6

DRAGEN Single Cell 4.4.4

Manual App Launch

11

DRAGEN Reference Builder 4.4.4001