> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/software/dragen/software-dragen-faq-list/000007537.md). Agents can also search and read this documentation through its [MCP server](https://knowledge.illumina.com/~gitbook/mcp).

# How is zygosity assigned for mitochondrial variant calls with DRAGEN?

Typically, there are approximately 100 mitochondria in each mammalian cell. Each mitochondrion harbors 2-10 copies of mitochondrial DNA (mtDNA).

DRAGEN processes **chrM** (mitochondrial chromosome) through a **continuous Allele Frequency (AF)** pipeline (similar to the Somatic Variant Calling pipeline). In this case a single ALT allele is considered and the **AF** is estimated, which can be between **0% and 100%**.

DRAGEN 4.5 User guide indicated the default variant AF thresholds are applied to mitochondrial variant calling:

* * `--vc-enable-af-filter-mito` Whether to enable the allele frequency for mitochondrial variant calling. The default is true.
  * `--vc-af-call-threshold-mito` Set the threshold for emitting calls in the VCF. The default is 0.01.
  * `--vc-af-filter-threshold-mito` Set the threshold to mark emitted vcf call as filtered. The default is 0.02.

QUAL and GQ value are not output in the chrM variant records. Instead, the confidence score is **FORMAT/SQ**, which gives the Phred-scaled confidence that a variant is present at a given locus.

\##FORMAT=\<ID=SQ,Number=A,Type=Float,Description="Somatic quality">

The decision to emit a variant or not is decided by comparing the FORMAT/SQ score to a threshold.

* If FORMAT/SQ < vc-sq-call-threshold, the variant is not output in the variant call file (VCF), and is banded in a \<NON\_REF> region with FORMAT/GT set to 0/0 (homoplasmic).
* If FORMAT/SQ > vc-sq-call-threshold but FORMAT/SQ < vc-sq-filter-threshold, the variant is emitted in the VCF but FILTER=weak\_evidence.
* If FORMAT/SQ> vc-sq-call-threshold, FORMAT/SQ > vc-sq-filter-threshold, and no other filters are triggered, the variant is output in the VCF and FILTER=PASS.
  * In DRAGEN v3.x (prior to v4.0.3), the FORMAT/GT is hard coded to 0/1 irrespective of the AF (heteroplasmic).
  * In DRAGEN v4.0. and higher, the FORMAT/GT is set to 1/1 if FORMAT/AF is > 95% (homoplasmic) and is set to 0/1 if FORMAT/AF is < 95% (heteroplasmic).

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                 |
| :-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #7537), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000007537%20-%20Software%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://knowledge.illumina.com/software/dragen/software-dragen-faq-list/000007537.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.