How is zygosity assigned for mitochondrial variant calls with DRAGEN?
Typically, there are approximately 100 mitochondria in each mammalian cell. Each mitochondrion harbors 2-10 copies of mitochondrial DNA (mtDNA).
DRAGEN processes chrM (mitochondrial chromosome) through a continuous Allele Frequency (AF) pipeline (similar to the Somatic Variant Calling pipeline). In this case a single ALT allele is considered and the AF is estimated, which can be between 0% and 100%.
DRAGEN 4.5 User guide indicated the default variant AF thresholds are applied to mitochondrial variant calling:
--vc-enable-af-filter-mitoWhether to enable the allele frequency for mitochondrial variant calling. The default is true.--vc-af-call-threshold-mitoSet the threshold for emitting calls in the VCF. The default is 0.01.--vc-af-filter-threshold-mitoSet the threshold to mark emitted vcf call as filtered. The default is 0.02.
QUAL and GQ value are not output in the chrM variant records. Instead, the confidence score is FORMAT/SQ, which gives the Phred-scaled confidence that a variant is present at a given locus.
##FORMAT=<ID=SQ,Number=A,Type=Float,Description="Somatic quality">
The decision to emit a variant or not is decided by comparing the FORMAT/SQ score to a threshold.
If FORMAT/SQ < vc-sq-call-threshold, the variant is not output in the variant call file (VCF), and is banded in a <NON_REF> region with FORMAT/GT set to 0/0 (homoplasmic).
If FORMAT/SQ > vc-sq-call-threshold but FORMAT/SQ < vc-sq-filter-threshold, the variant is emitted in the VCF but FILTER=weak_evidence.
If FORMAT/SQ> vc-sq-call-threshold, FORMAT/SQ > vc-sq-filter-threshold, and no other filters are triggered, the variant is output in the VCF and FILTER=PASS.
In DRAGEN v3.x (prior to v4.0.3), the FORMAT/GT is hard coded to 0/1 irrespective of the AF (heteroplasmic).
In DRAGEN v4.0. and higher, the FORMAT/GT is set to 1/1 if FORMAT/AF is > 95% (homoplasmic) and is set to 0/1 if FORMAT/AF is < 95% (heteroplasmic).