> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/software/basespace-sequence-hub/software-basespace-sequence-hub-troubleshooting-list/000007380.md).

# What to do if a BaseSpace analysis is stuck or stalled running

If an analysis is taking longer than it typically does in BaseSpace, consider the following before using the steps outlined in this article:

1. Is the analysis demultiplexing or analyzing more data than in the past from the same instrument?
2. Is the analysis demultiplexing or analyzing data on an instrument that is different than the instrument typically used?
3. Is BaseSpace performing normally?

If at least one if the above is true, allow the analysis to continue running for some additional time. If an analysis is performing correctly, stopping and restarting the analysis may increase the turnaround time of the analysis.

**Note**: Analysis using the BaseSpace Apps listed in [Which BaseSpace apps and features use Illumina BioInsight Platform Core](/software/general/software-general-reference_material-list/000009045.md) will display the status Running, but they may be queued in Illumina BioInsight Platform Core (formerly, Illumina Connected Analytics (ICA)). Refer to the [Illumina Status page](https://status.illumina.com/) to assess the current operational status.

If the analysis does need to be stopped and restarted, follow the steps below.

**How to Stop and Requeue a FASTQ Generation App Session**:

1. Navigate to the FASTQ Generation session to be stopped.
2. Select the Status option ![](/files/XEmo9qRWD7EDFB4UuXPI)\
   then select **Cancel** > **Analysis**.
   * Once the analysis is stopped it shows as **Aborted** in the Status line.
3. Navigate to the Run to be requeued for demultiplexing.
4. Select the Status option ![](/files/qvGadhJanepMgvqoei8Z)\
   then select **Requeue** > **Sample Sheet**.
5. The screen that follows is prepopulated with the original sample sheet that was provided during run set up. Paste a new sample sheet from a csv text file or leave the prepopulated sample sheet as is.
6. Once the message states that the "**Sample sheet is valid**" select the **Queue Analysis** option.
7. The FASTQ Generation session has now been requeued.

**How to Stop and Requeue BaseSpace App Analysis**:

1. Navigate to the App session to be stopped.
2. Select the Status option ![](/files/zwArSquU9UcBwLfSe6DC)\
   then select **Cancel** > **Analysis**.
3. Once the analysis stops and shows **Aborted** in the Status line, start a new analysis.

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                 |
| :-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #7380), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000007380%20-%20Software%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://knowledge.illumina.com/software/basespace-sequence-hub/software-basespace-sequence-hub-troubleshooting-list/000007380.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
