What to do if a BaseSpace analysis is stuck or stalled running
If an analysis is taking longer than it typically does in BaseSpace, consider the following before using the steps outlined in this article:
Is the analysis demultiplexing or analyzing more data than in the past from the same instrument?
Is the analysis demultiplexing or analyzing data on an instrument that is different than the instrument typically used?
Is BaseSpace performing normally?
If at least one if the above is true, allow the analysis to continue running for some additional time. If an analysis is performing correctly, stopping and restarting the analysis may increase the turnaround time of the analysis.
Note: Analysis using the BaseSpace Apps listed in Which BaseSpace apps and features use Illumina BioInsight Platform Core will display the status Running, but they may be queued in Illumina BioInsight Platform Core (formerly, Illumina Connected Analytics (ICA)). Refer to the Illumina Status page to assess the current operational status.
If the analysis does need to be stopped and restarted, follow the steps below.
How to Stop and Requeue a FASTQ Generation App Session:
Navigate to the FASTQ Generation session to be stopped.
Select the Status option
then select Cancel > Analysis.Once the analysis is stopped it shows as Aborted in the Status line.
Navigate to the Run to be requeued for demultiplexing.
Select the Status option
then select Requeue > Sample Sheet.The screen that follows is prepopulated with the original sample sheet that was provided during run set up. Paste a new sample sheet from a csv text file or leave the prepopulated sample sheet as is.
Once the message states that the "Sample sheet is valid" select the Queue Analysis option.
The FASTQ Generation session has now been requeued.
How to Stop and Requeue BaseSpace App Analysis:
Navigate to the App session to be stopped.
Select the Status option
then select Cancel > Analysis.Once the analysis stops and shows Aborted in the Status line, start a new analysis.
For any feedback or questions regarding this article (Illumina Knowledge Article #7380), contact Illumina Technical Support techsupport@illumina.com.