> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/microarray/tecan-iaps/microarray-tecan-iaps-faq-list/000007003.md).

# Cleaning agents specifications and applications for Tecan (LiHa and RoMa) parts

Clean each component of the Tecan instrument, specifically the LiHa (Liquid Handling Arm) and RoMa (Robotic Manipulator), on a regular basis using only the specified and appropriate cleaning agents for each part. Proper cleaning is essential to maintain instrument performance, accuracy, and longevity.

Using incorrect cleaning agents, harsh chemicals, or strong detergents can damage the instrument. In particular, these substances may dissolve or degrade the protective coatings on carriers and worktable surfaces, leading to premature wear, corrosion, or functional issues that can negatively affect assay performance.

The tables below provide detailed guidance on:

* The recommended cleaning agents for each Tecan component
* Specifications and usage considerations for each cleaning agent
* Manufacturers of commercially available cleaning products

**Table 1.** Cleaning agents that can be used for each Tecan parts.

<table data-header-hidden><thead><tr><th valign="top"></th><th valign="top"></th></tr></thead><tbody><tr><td valign="top"><strong>Instrument part</strong></td><td valign="top"><strong>Cleaning agent</strong></td></tr><tr><td valign="top">Liquid system, including waste system</td><td valign="top"><p>Water, alcohol, weak detergent, base</p><p>Suitable for flushing are: Bleach, Decon / Contrad, Terralin</p><p>protect</p></td></tr><tr><td valign="top">Worktable</td><td valign="top">Water, alcohol, weak detergent, disinfectant, base, bleach</td></tr><tr><td valign="top">Housing</td><td valign="top">Water, alcohol, surface disinfectant</td></tr><tr><td valign="top">Metal parts</td><td valign="top">Water, alcohol, disinfectant</td></tr><tr><td valign="top">Carriers</td><td valign="top">Water, alcohol, weak detergent, disinfectant Use: Decon / Contrad for surface cleaning only Do not use: Decon / Contrad, Bleach, SporGon as cleaning bath for carriers (damage to aluminum)</td></tr><tr><td valign="top">Racks</td><td valign="top">Water, alcohol, weak detergent, disinfectant</td></tr><tr><td valign="top">Gripper</td><td valign="top">Water, alcohol, weak detergent, disinfectant</td></tr><tr><td valign="top">Tips</td><td valign="top">Water, alcohol, weak detergent, disinfectant, base</td></tr><tr><td valign="top">Safety panels</td><td valign="top">Water, alcohol, disinfectant, suitable for acrylic glass</td></tr><tr><td valign="top">Disposable tip cones</td><td valign="top">Alcohol</td></tr><tr><td valign="top">PosID scanner head laser beam output window</td><td valign="top">Alcohol</td></tr><tr><td valign="top">Arm guide, arm guide roller of arms</td><td valign="top">Do not use any agent</td></tr><tr><td valign="top">Z-rod</td><td valign="top">Do not use any agent</td></tr></tbody></table>

**Table 2.** Specifications for each cleaning agent.

<table data-header-hidden><thead><tr><th valign="top"></th><th valign="top"></th></tr></thead><tbody><tr><td valign="top"><strong>Agent</strong></td><td valign="top"><strong>Specifications</strong></td></tr><tr><td valign="top">Water</td><td valign="top">Distilled or deionized water</td></tr><tr><td valign="top">Alcohol</td><td valign="top">70% ethanol or 100% isopropanol (2-Propanol)</td></tr><tr><td valign="top">Decon / Contrad</td><td valign="top">Liquid concentrate, for dilution with water (normally 2%, 5% in case of severe contamination)</td></tr><tr><td valign="top">Weak detergent</td><td valign="top">eg, Liqui-Nox</td></tr><tr><td valign="top">Disinfectant</td><td valign="top">eg, Bacillol plus, SporGon</td></tr><tr><td valign="top">Surface disinfectant</td><td valign="top">All disinfectants except: Lysetol FF, SporGon</td></tr><tr><td valign="top">Base</td><td valign="top">eg, 0.025-0.25 mol/l NaOH</td></tr><tr><td valign="top">Bleach</td><td valign="top">0.5% to 3% sodium hypochlorite</td></tr></tbody></table>

**Table 3.** Manufacturers of commercially available cleaning products.

<table data-header-hidden><thead><tr><th valign="top"></th><th valign="top"></th><th valign="top"></th></tr></thead><tbody><tr><td valign="top"><strong>Agent</strong></td><td valign="top"><strong>Description</strong></td><td valign="top"><strong>Manufacturer</strong></td></tr><tr><td valign="top">Contrad 70<sup>*</sup></td><td valign="top">Surface active cleaning agent</td><td valign="top">Decon Labs Inc., USA www.deconlabs.com</td></tr><tr><td valign="top"><p>Contrad 90*</p><p>Contrad 2000*</p></td><td valign="top">Surface active cleaning agent</td><td valign="top">Decon Laboratories Limited, UK www.decon.co.uk</td></tr><tr><td valign="top">Decon 90*</td><td valign="top">Surface active cleaning agent</td><td valign="top">Decon Laboratories Limited, UK www.decon.co.uk</td></tr><tr><td valign="top">Bacillol Plus</td><td valign="top">Alcoholic, disinfection agent, free of formaldehyde, for surface cleaning</td><td valign="top">Bode Chemie, Hamburg www.bode-chemie.de</td></tr><tr><td valign="top">DNAzap</td><td valign="top">Cleaning agent for surfaces contaminated with nucleic acids</td><td valign="top"><p>Ambion</p><p>www.ambion.com</p></td></tr><tr><td valign="top">SporGon</td><td valign="top">Disinfectant</td><td valign="top">Decon Laboratories www.deconlabs.com</td></tr><tr><td valign="top">Liqui-Nox</td><td valign="top">Weak detergent</td><td valign="top"><p>Alconox</p><p>www.alconox.com</p></td></tr></tbody></table>

\*These are identical products; are hereafter called Decon / Contrad

**Notes:**

* If weak detergents, base or bleach, are used, thoroughly clean with water and wipe dry to remove the cleaning agent and obtain normal operating conditions.
* Use a lint-free tissue together with the appropriate cleaning agent.

For further information, see [Operating Manual Infinium LiHa and Infinium RoMa](https://support.illumina.com/downloads/infinium-liha-infinium-roma-manual-1000000110155.html) guide.

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                   |
| :---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #7003), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000007003%20-%20Microarray%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://knowledge.illumina.com/microarray/tecan-iaps/microarray-tecan-iaps-faq-list/000007003.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.