Infinium Methylation Screening Array Manifest Column Headings

This article provides detailed descriptions of the column headings in the Infinium Methylation Screening (MSA) Array Manifest File (CSV). The associated product files can be accessed from the Infinium Methylation Screening Array Product Files page. The sections below describe each manifest column heading and the corresponding information provided to support data analysis, annotation, and interpretation.

IlmnID

Unique identifier extended with the following design strand designations

  • Illumina strand (T/B)

  • Assay Strand (C / O)

  • Infinium Design Type (1/2)

  • Rep_Num

Name

Unique identifier from the Illumina CG database

AddressA_ID

For Infinium I beadtypes, this is the Address ID for the probe specific for the A allele

For Infinium II beadtypes, this is the Address ID for the probe used for both A and B alleles (in this case AddressB_ID and AlleleB_ProbeSeq columns will be empty)

AlleleA_ProbeSeq

The sequence of the probe identified in the AddressA_ID column

AddressB_ID

For Infinium I beadtypes, this is the Address ID for the probe specific for the B allele

AlleleB_ProbeSeq

For Infinium I beadtypes, the sequence of the probe identified in the AddressB_ID column

Next_Base

For Infinium I probes, the nucleotide immediately following the CpG. Blank for Infinium II

Color_Channel

For Infinium I probes, the color channel of the Next_Base signal (Red/Green)

col

Color_Channel: For Infinium I probes the color channel of the Next_Base signal (R/G). Used for Bioconductor methylation array analysis software tools

Probe_Type

Probe type

  • cg=CpG

  • rs=dbSNP rsID

  • ch=Cp

Strand_FR

The Forward (F) or Reverse (R) designation of the Design Strand. F is equal to reference + strand

Strand_TB

The Illumina Top (T) or Bottom (B) designation of the Design strand

Strand_CO

The assay Converted (C) or Opposite (O) designation of the Design strand

Infinium_Design

Infinium Design (1) - 2 probes or (2) - 1 probe. Used for Bioconductor methylation array analysis software tools

Infinium_Design_Type

Infinium I (2 probes/locus) or Infinium II (1 probe/locus)

Rep_Num

Reflects the replicate number if the Name has replicate designs

CHR

Chromosome containing the CpG (GRCh38)

MAPINFO

Chromosomal coordinates of the CpG (GRCh38)

Species

Species which the assays were designed for (Homo sapiens)

Genome_Build

Genome Build referenced for this manifest

Source_Seq

The original genomic sequence used for probe design prior to bisulfite conversion

Forward_Sequence

Plus (+) strand sequence (5'-3') flanking the CG

Top_Sequence

Top strand sequence (5'-3') flanking the CG

UCSC_RefGene_Group

NCBI RefSeq Gene region

  • 5UTR=5' untranslated region between the TSS and ATG start site

  • 3UTR=3' untranslated region between stop codon and poly A signal

  • exon_#

  • TSS200=1-200 bp 5' the TSS

  • TSS1500=200-1500 bp 5' of the TSS

  • Intronic regions included

UCSC_RefGene_Name

NCBI RefSeq Gene Name: Target gene names from the RefSeq database. Multiple listings of the same gene name indicate splice variants

UCSC_RefGene_Accession

NCBI RefSeq Transcript ID: The RefSeq accession numbers of the target transcripts. Accession numbers are in the same order as the target gene transcripts

UCSC_CpG_Islands_Name

Chromosomal coordinates of the CpG Island from UCSC.

Relation_to_UCSC_CpG_Island

  • Island=within boundaries of a CpG Island

  • N_Shore=0-2kb 5' of Island

  • N_Shelf=2kb-4kb 5' of Island

  • S_Shore=0-2kb 3' of Island

  • S_Shelf=2kb-4kb 3' of Island

GencodeV41_Group

Gencode v41 Gene region

  • 5UTR=5' untranslated region between the TSS and ATG start site

  • 3UTR=3' untranslated region between stop codon and poly A signal

  • exon_#, TSS200=1-200 bp 5' the TSS

  • TS1500=200-1500 bp 5' of the TSS

  • Intronic regions included

GencodeV41_Name

Gencode v41 Gene Name: Target gene names from the RefSeq database. Multiple listings of the same gene name indicate splice variants

GencodeV41_Accession

Gencode v41 Transcript ID: The RefSeq accession numbers of the target transcripts. Accession numbers are in the same order as the target gene transcripts

Phantom5_Enhancers

Chromosomal coordinates from the FANTOM consortium of enhancer regions associated with FANTOM5 promoters

HMM_Island

Hidden Markov Model Islands. Chromosomal map coordinates of computationally predicted CpG islands

Regulatory_Feature_Name

Chromosomal map coordinates of the regulatory feature (informatically determined by the original ENCODE Consortium)

Regulatory_Feature_Group

Description of the regulatory feature referenced in Regulatory_Feature_Name as provided by the original ENCODE Consortium - Gene_Associated, Gene_Associated _Cell_type_specific, nonGene_Associated, Promoter_Associated_Cell_type_specific, Unclassified, Unclassified_Cell_type_specific

DNase_Hypersensitivity_NAME

Name of the DNase Hypersensitivity site as defined in ENCODE v5

Encode_CisReg_Site

Name and classification of the CisRegulatory Region as defined in ENCODE v5

Encode_CisReg_Site_Evid

Evidence for each CisReg Region/Classification based on 87 studies in ENCODE v5 based on AllData-Full classification

OpenChromatin_NAME

Classification of Open Chromatin sites based on 1600+ studies in ENCODE v5

OpenChromatin_Evidence_Count

Evidence for each Open Chromatin site classification based on 1600+ studies in ENCODE v5

EPICv2_Locus_Match

Locus Name (IlmnID) in Infinium MethylationEPICv2.0 Manifest

EPICv1_Locus_Match

Locus Name (IlmnID) in Infinium MethylationEPICv1.0 Manifest

Methyl450_Locus_Match

Locus Name (IlmnID) in Infinium Methylation450K Manifest

EPICv2_ProbeSeq_Match

Indicates if the AlleleA_ProbeSeq matches for EPIC v2

EPICv1_ProbeSeq_Match

Indicates if the AlleleA_ProbeSeq matches for EPIC v1

Methyl450_ProbeSeq_Match

Indicates if the AlleleA_ProbeSeq matches for Methylation450K

SNP_ID

rsIDs of SNPs located in the probe. Multiple listings of SNP rsIDs are allowed. dbSNP v155 used as reference

SNP_DISTANCE

Distance of SNPs from query base of the probe. Multiple listings of the distance values are associated with rsid. dbSNP v155 used as reference

SNP_MinorAlleleFrequency

Minor allele frequency of SNPs. Multiple listings of the minor allele frequencies are associated with rsid. dbSNP v155 used as reference

CHR_GRCh37

Chromosome containing the CpG (GRCh37)

MAPINFO_GRCh37

Chromosomal coordinates of the CpG (GRCh37)