> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/microarray/general/microarray-general-reference_material-list/000010127.md).

# Download and installation of Dragen array software for local analysis

**Steps for downloading the Dragen array installer:**

1. Access the [Illumina website for DRAGEN Array Secondary Analysis Software Downloads,](https://support.illumina.com/array/array_software/dragen-array-secondary-analysis/downloads.html) and Click the link of the DRAGEN Array Installer for Linux or Windows:

![](/files/BynVCd8tuGU9M2yhVZRF)

2. You will be directed to log in [MyIllumina account](https://my.illumina.com/welcome) (create an account if you don’t have one yet)

Step 1:

![](/files/8XQoA0CpUmHRfHydKiYY)

Step 2:

![](/files/3rOj6duKZfJg0oanb988)

3. You will be asked to enter your Illumina customer number or the serial number of an Illumina instrument:

![](/files/sUZsTXO4nQtld18QU9BU)

4. You will then be asked to browse to a location in your computer where you want to download/save to installer:

![](/files/DUnJlaGpuB4s6dRiINNs)

**Installation of Dragen array software**

1. Once download is completed, move the DRAGEN Array installation package to the desired folder. Administrative permissions may be required for system folders, for example C:\Program Files for Windows:

![](/files/cojYCr8El9SWGzLko8Cm)

2. When you click the dragen.exe from the folder where it was saved, a Command Prompt (cmd)window will open and close in seconds, you might not see it, as it happens fast.

![](/files/y08GoouZKwVXRakvEbwc)

3. To check that the files have been installed properly, execute the following commands in cmd:

![](/files/fdvjip4zl8cTo0qB5BT9)

(P.S. screenshot was redacted to hide the username of the folder owner where the software was installed)

The commands from the cmd screenshot above are listed below:

1. 1. Copy the path to the location of the installed dragena software:

![](/files/qftSLniVhwrQkRo2HkPG)

1. 2. Paste the copied Dragena path after the command cd:

**b.1)** C:>**cd** C:\Users\*username\*\Apps\dragena-win-x64-DAv1.3.0-rc3-sha.f3fec02ebf2c43d3f3d6327cbe3b410edbc167b4\dragena-win-x64-DAv1.3.0-rc3-sha.f3fec02ebf2c43d3f3d6327cbe3b410edbc167b4\dragena

**b.2)** You should get the following response if the connection to the software location can be established:

C:\Users\*username\*\Apps\dragena-win-x64-DAv1.3.0-rc3-sha.f3fec02ebf2c43d3f3d6327cbe3b410edbc167b4\dragena-win-x64-DAv1.3.0-rc3-sha.f3fec02ebf2c43d3f3d6327cbe3b410edbc167b4\dragena>

**b.3)** Enter the command “dragena version”:

C:\Users\username\Apps\dragena-win-x64-DAv1.3.0-rc3-sha.f3fec02ebf2c43d3f3d6327cbe3b410edbc167b4\dragena-win-x64-DAv1.3.0-rc3-sha.f3fec02ebf2c43d3f3d6327cbe3b410edbc167b4\dragena>dragena version

**b.4)** You should get as response the version of the installed Dragen array software:

DRAGEN Array CLI 1.3.0

**Note:**

Dragen array software is not a graphical user interface (GUI), it is a command line interface (CLI), user will need to open Command Prompt (cmd) or PowerShell to use Dragen array local.

To open Command Prompt (cmd) on a Windows computer, press Win icon + R, type cmd into the Run dialogue box, and press Enter.

![](/files/QY4A8pvCRx1Sfwj2rvpT)

Alternatively, search for "cmd" or "Command Prompt" in the taskbar's search bar and select the application from the results.

**Additional useful references:**

* [DRAGEN Array Local Analysis guide](https://help.dragenarray.illumina.com/product-guides/dragen-array-local-analysis)

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                    |
| :----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #10127), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000010127%20-%20Microarray%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://knowledge.illumina.com/microarray/general/microarray-general-reference_material-list/000010127.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.