> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/microarray/general/microarray-general-reference_material-list/000006249.md).

# Equipment used in the Infinium XT protocol

**Hybridization**

1. **XT Hyb Chamber (PN: 20011755) + Gasket (PN: 20012127)**

* Image of XT Hyb Chamber and Gasket:

  ![](/files/aoeDfmuJqKPUfveStghD)

2. **XT Dual Hyb Inserts and Baseplates (PN: 20011759):**

* These parts have a dual purpose, as a Hyb chamber assembly insert and a baseplate for the XT BeadChips on the Tecan deck during Hybridization:

Used to hold BeadChips 1) on the Tecan deck and 2) inside the XT Hyb chambers.

* Up to three XT Dual Hyb Insert and Baseplate can fit into one XT Hyb chamber, holding a total of up to six XT BeadChips.
* Image on Placing BeadChips on Baseplates:

  ![](/files/GtAmPxtl2t8DUI84hzVq)
* Image of XT Hyb Chamber and three XT dual Hyb inserts and baseplates:

  ![](/files/q8BFHAXoLs2GEGpLZvWN)

3. **Infinium 96-XT Tip Guide Set (PN: 20011102)**

* Comes with:
  * XT Tip Guide #1 is used to load samples from sample well columns 1-4.
  * XT Tip Guide #2 is used to load samples from sample well columns 5-8.
  * XT Tip Guide #3 is used to load samples from sample well columns 9-12.
* Image of Tip Guides and XT plate layout:

  ![](/files/VVimEib3rCZIZbZ1GKRp)

**XStain**

4. **XT (XCG) Flow-Through Chamber Assembly Tray (PN: 20011760)**

* Tray to hold up to six XT BeadChips in frames during flow-through chamber assembly.
* No alignment bar included.
* Image of XT Flow-Through Chamber Assembly Tray:

  ![](/files/YvQ1LIBTDJfro5XOctgR)

5. **XT (XCG) Flow-Through Chamber Frames (PN: 20011757 for set of 8)**

* Supports XT BeadChips during flow-through chamber assembly.
* Image of the XT Frame

  ![](/files/E5I68DavPNRKlFN1jWyQ)

6. **XT (XCG) Flow-Through Chambers (set of 8, PN: 20012129)**

* Includes XCG glass back plates, XCG clips, and XCG frames
* Image of XCG glass back plates, XCG clips, and XCG frames (BeadChip not included)

  ![](/files/fG9GCN3HrW4X4mU2zcAh)

7. **XT (XCG) Glass Back Plates**

* This glass back plate has an integrated spacer.

  * PN: 20011756 for a set of 8

  ![](/files/e94IqCE74mtWRsRH3UwU)

9. **XT (XCG) Flow-Through Chamber Clamps (Clips)**

* To secure the glass back plate onto the BeadChip.
  * PN: 20007046 for 1
  * PN: 20011758 for set of 16

Reference:[Infinium XT Assay Reference Guide for the ST Workflow](https://support.illumina.com/downloads/infinium-xt-st-reference-guide-1000000025687.html)\
\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                   |
| :---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #6249), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000006249%20-%20Microarray%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://knowledge.illumina.com/microarray/general/microarray-general-reference_material-list/000006249.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
