For the complete documentation index, see llms.txt. This page is also available as Markdown.

How to download and install DRAGEN Array software for Local Analysis

DRAGEN (Dynamic Read Analysis for GENomics) Array is a secondary bioinformatics analysis tool for Illumina Infinium assays. It is available as both a local package with a command-line interface and a cloud-based package with a graphical user interface (GUI).

Downloading the DRAGEN Array installer:

  1. Navigate to the DRAGEN Array Secondary Analysis Software Downloads page on the Illumina website (Figure 1), and click the appropriate DRAGEN Array Installer link for either Linux or Windows.

Figure 1. DRAGEN Array Secondary Analysis Software Downloads page showing the installation packages for Linux and Windows.

  1. Log in with a MyIllumina account. If an account is not available, select Sign up and follow the prompts to create a new account (Figure 2).

Figure 2: Log in screen for accessing the MyIllumina account.

Note: If user has already signed up and has one or more domains associated with their MyIllumina account, select the appropriate domain (Figure 3), Then, select Accounts to proceed.

Figure 3. Sign-in screen for accessing a MyIllumina account when one or more domains are associated with the account.

  1. Enter an Illumina customer number or the serial number of an Illumina instrument (Figure 4).

Figure 4. Pop-up window used to enter an Illumina customer number or the serial number of an Illumina instrument.

  1. Browse to the desired location on the computer to download/save the installer:

Figure 5. Windows download screen for saving the DRAGEN Array Local installer package for Windows.

Installation of DRAGEN Array software

This section provides examples of the installation process on a Windows system. For detailed instructions on installing DRAGEN Array Local on Linux systems, refer to the DRAGEN Array Local Analysis Installation guide.

  1. Once the download is complete, move the DRAGEN Array installation package to the desired folder. Administrative permissions may be required when installing to system directories, such as /usr/local/bin on Linux or C:\Program Files on Windows.

  2. Unzip and extract the package. The executable (dragena.exe) is located in the dragena subfolder of the installation package (Figure 6).

Figure 6. Location of thedragena executable in the dragena subfolder.

  1. When the dragena.exe executable is launched from the folder where it was saved, a Command Prompt (cmd) window may briefly open and close within a few seconds. This occurs quickly and may not be visible to the user.

Figure 7. Command Prompt (cmd) window displayed temporarily while dragena.exe is executed.

  1. To verify that the files were installed correctly, open a Command Prompt in the dragena folder by typing cmd in the File Explorer address bar and pressing Enter (Figure 8A).

In the Command Prompt window, enter the following command: dragena version and press Enter.

The command returns the installed DRAGEN Array CLI version. For example, DRAGEN Array CLI 1.4.0+9b051a4be2c6ade41bfa804c3bccc41cdbdc1c5b (Figure 8B).

Figure 8. A: Opening a Command Prompt (cmd) window from within the dragena folder. B: Verifying successful installation by displaying the installed DRAGEN Array version.

Notes:

DRAGEN Array Local Analysis software does not include a graphical user interface (GUI); it is a command-line interface (CLI) application. Users who are new to working with CLI applications may refer to DRAGEN Array Tips for using the Command-line interface for additional guidance.

When running DRAGEN Array Local on Windows systems, users will need to open the Command Prompt (cmd) or PowerShell. This can be either done as described above, or by pressing Win + R, type cmd into the Run dialogue box, and press Enter.

Figure 9. Launching Command Prompt from the Windows Run dialog box by enteringcmd.

Alternatively, open Command Prompt by entering "cmd" or "Command Prompt" in the Windows taskbar search box and selecting the application from the displayed results.

Reference:

DRAGEN Array Local Analysis guide

For any feedback or questions regarding this article (Illumina Knowledge Article #10127), contact Illumina Technical Support techsupport@illumina.com.

Last updated

Was this helpful?