> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/library-preparation/illumina-single-cell/library-preparation-illumina-single-cell-reference_material-list/000009437.md).

# Best practices for cell preparation for Illumina Single Cell 3' RNA prep

Sample quality is critical for optimal results with Illumina Single Cell 3' RNA Prep. Ideal cell suspensions are 90% viable or higher, and contain minimal debris or aggregates.

The best option is to start with fresh cells whenever possible, and nuclei sequencing is required when starting from frozen tissue. See [Best practices for using Illumina Single Cell Nuclei Isolation Kits for Illumina Single Cell kits](/library-preparation/illumina-single-cell/library-preparation-illumina-single-cell-reference_material-list/000009450.md) for more information.

If cells are handled too roughly, cells will lyse which can increase background mRNA. To minimize damage during sample preparation, pipetting and centrifugation should be kept to a minimum. Tightly packed cell pellets require extra pipetting, which can damage cells from shearing effects. Pipetting steps should be slow and gentle, and the use of wide-bore tips is recommended to minimize shear forces on the cell suspension.

It can be necessary to use standard-bore tips in some cell/sample types to reduce clumps.

**Figure 1**. Common Cell Preparation Reagents that are Incompatible with Illumina Single Cell

![](https://761066130-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGM9W2DuBTgEXv1ClCm8H%2Fuploads%2Fgit-blob-77e293a6b6eb231a96719489d25742bc1ccc036d%2Fimage1.png?alt=media)

It is critical to complete the Cell Suspension Buffer Wash of cell suspensions prior to input into the PIPs to ensure any inhibitory reagents are sufficiently washed out of the cell suspension.

DNase I can break down the cell barcode structure and PolyA capture moiety on PIPs. If DNase I must be used, make sure it is thoroughly washed out of the cell suspension by doing at least three 2 ml PBS washes followed by a 1 ml Illumina Single Cell Suspension Buffer wash.

User supplied RNase Inhibitor (0.4-1 U/μl) may need to be added to any buffers during cell preparation of time-consuming steps (eg, antibody staining buffers, FACS collection tube buffers, and the final cell suspension during cell counting and viability checking).

Including RNase Inhibitor in upstream processes is especially important for challenging sample types with high endogenous RNase and/or low mRNA content (eg, neutrophiles, eosinophils, adipose, pancreas, spleen, machrophages, etc.). It is usually not necessary to add RNase inhibitors for washing steps and washing buffers unless working with granulocytes.

Illumina Single Cell 3' RNA prep kits provide enough RNase Inhibitor to add to samples into the PIP tube during the Capture and Lysis portion of the workflow.

**If there is an expected delay between completing cell counting and viability assessment**, **and starting the Capture and Lysis step**, **RNase Inhibitors should be added directly into the diluted cell suspension instead of spiked in separately into the PIP tube during sample addition**.

For more information refer to Section 2 in the Illumina Single Cell 3' RNA Prep [Training Packet](https://support.illumina.com/sequencing/sequencing_kits/illumina-single-cell-prep/training.html).

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                              |
| :--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #9437), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000009437%20-%20Library%20Preparation%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://knowledge.illumina.com/library-preparation/illumina-single-cell/library-preparation-illumina-single-cell-reference_material-list/000009437.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.