> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/library-preparation/general/library-preparation-general-reference_material-list/000003426.md).

# Respiratory Virus Enrichment Kit sequencing recommendations and public data resources

**What is the recommended read length?**\
A 2x75 bp read length is recommended when sequencing Respiratory Virus Enrichment Kit (RVEK) libraries, prepared with the Respiratory Virus Oligos Panel v2 (RVOP v2). This shorter read length takes into account the potentially shorter average size of libraries created with samples of variable quality.

**What is the recommended read depth?**\
1 million reads per sample are recommended as a starting point, labs can adjust based on data needs.

**Are there public datasets available?**\
Yes, the following public datasets are available in BaseSpace Sequence Hub.\
(**Note**: BaseSpace login is required to access the following links.)

iSeq 100: Illumina RNA Prep with Enrichment and RVOPv2 (SARS-CoV-2 Synthetic RNA Control)\
[Run Link](https://basespace.illumina.com/s/HwSmqlEqdffD)\
[Project Link](https://basespace.illumina.com/s/M9fzI7UPAaZg)

MiniSeq: Illumina RNA Prep with Enrichment and RVOPv2 (SARS-CoV-2 Synthetic RNA Control)\
[Run Link](https://basespace.illumina.com/s/8Y8CSJVhyRSj)\
[Project Link](https://basespace.illumina.com/s/644AIyHluDsv)

MiSeq: Illumina RNA Prep with Enrichment and RVOPv2 (SARS-CoV-2 Synthetic RNA Control)\
[Run Link](https://basespace.illumina.com/s/ivK345PD6ygE)\
[Project Link](https://basespace.illumina.com/s/Mrb9N3kgX10m)

NextSeq 550: Illumina RNA Prep with Enrichment and RVOPv2 (SARS-CoV-2 Synthetic RNA Control).\
[Run Link](https://basespace.illumina.com/s/ij2AEQzYrrQg)\
[Project Link](https://basespace.illumina.com/s/6GDd5A2q1xHu)

Please note that this kit was previously named the Respiratory Virus Oligo Panel v2 kit, and has been renamed to the Respiratory Virus Enrichment Kit, which still uses the Respiratory Virus Oligo Panel v2 for enrichment.

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                              |
| :--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #3426), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000003426%20-%20Library%20Preparation%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://knowledge.illumina.com/library-preparation/general/library-preparation-general-reference_material-list/000003426.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.