> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/library-preparation/general/library-preparation-general-faq-list/000010210.md).

# Kits, consumables, and reagent stability FAQ for Illumina Rapid RNA Kits

**How many times can the Rapid RNA prep reagents be freeze/thawed?**

Illumina has tested up to 6 freeze-thaw cycles with confirmed product performance.

**What must be purchased for a Rapid RNA workflow? Are the kits bundled, or modular? If modular, what is needed?**

* The Rapid mRNA, Total RNA, and RNA with Enrichment are **modular**, and each Rapid RNA prep product page lists the components needed for the complete workflow.
* The catalog products are **bundled** for the Rapid RNA Prep with Exome 2.5 Enrichment, VSPv2, RPIP, and RVEK, including the Rapid RNA prep, Fast Hyb Enrichment and Oligo panels.
* Illumina DNA/RNA UD Indexes are sold separately for all workflows.

**For Rapid Enrichment products, how many samples for library prep and how many enrichment reactions do the products support? Is this different from the non-Rapid versions?**

Illumina Rapid RNA Prep with Enrichment(for custom enrichment panels):

* Library prep reagents are sold for either 16 samples (20158823) or 96 samples (20158824)
* Enrichment reagents are sold for either 16 samples (20040540, 16 hyb reactions), or for 96 samples (20040541, 32 hyb reactions)
* Typically, users will purchase 20158823 and 20040540 to process 16 samples at 1-plex, or they will purchase 20158824 and 20040541 to process 96 samples at 3-plex.

Illumina Rapid Exome 2.5, VSPv2, RPIP, RVEK: These bundled kits support 96 samples, at 3-plex enrichments (32 enrichment reactions).

These plexities are the same as their non-Rapid versions, where applicable.

**Compared to non-Rapid kits, are there any new consumables or equipment required for Rapid workflows?**

Generally, compared to their non-Rapid versions, no new equipment or consumables are needed for the Rapid workflows. However, one notable difference is that users of the Illumina Rapid mRNA prep kit may need to use a microsample incubator to heat ST2 if there is precipitate. Additionally, Rapid RNA guides have been updated to have more comprehensive lists of required consumables (such as, gloves, lab tape, all pipette tip sizes, updated thermal cycler recommendations, etc.). Always consult the User-Supplied Consumables and Equipment section of the Product Documentation to verify all the required materials before starting library preparation.

**Which indexes do Illumina Rapid RNA kits require? Where are their sequences listed?**

Illumina DNA/RNA UD Indexes sets A-D, Tagmentation (cat # 20091654, 20091656, 20091658, 20091660, respectively). Index sequences can be found in the [Adapter Sequences Document.](https://support.illumina.com/downloads/illumina-adapter-sequences-document-1000000002694.html)

**Do Rapid workflows utilize Unique Molecular Identifiers (UMIs)? If yes, where are they in the library?**

No, Rapid workflows do not utilize UMIs.

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                               |
| :---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #10210), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000010210%20-%20Library%20Preparation%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://knowledge.illumina.com/library-preparation/general/library-preparation-general-faq-list/000010210.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.