> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/library-preparation/general/library-preparation-general-faq-list/000009939.md).

# General FAQ for the Illumina 5 Base WGS and Enrichment kits

**How does the Illumina 5-Base solution work?**

* While conventional methylation conversion technologies convert unmethylated cytosine to thymine, Illumina proprietary conversion chemistry selectively converts methylated cytosine to thymine. As the majority of cytosines in a healthy human genome are unmethylated, selective conversion of methylated cytosine produces higher complexity libraries and, when combined with novel informatics, provides comprehensive, cost-effective 5-Base insights. The 5-Base assay can replace two separate genetic and epigenetic sequencing assays, saving time and budgets, with minimal incremental sequencing for methylation insights.
* **The novel chemistry allows direct conversion of 5mC to T**. The top row, below, represents input DNA, and the bottom row represents the converted DNA:

\*\* ![](/files/OfQpwZhNSMCLayNBmL8J)\
\*\*

**Which types of modifications does the Illumina 5-Base solution detect?**

* The Illumina 5-Base solution detects 5-methylcytosine (5mC) along with unmodified bases, adenine (A), thymine (T), guanine (G), and cytosine (C). DNA methylation is a key epigenetic modification to regulate gene expression.

**Does this product convert and detect both 5-methylcytosine (5mC), and 5-hydroxymethylcytosine (5hmC)?**

* The Illumina enzyme is very specific to converting 5mC, and has minimal activity on 5hmC.

**Can the 5-Base kit be used for methylated RNA?**

* The assay is only designed for DNA.

**How does the Illumina 5-Base solution compare to other NGS methylation solutions?**

* Common methods for detecting DNA methylation use bisulfite or enzymes to convert unmethylated C to T. This reduces nucleotide diversity, making reads harder to align. Bisulfite treatment can also damage DNA, leaving data gaps. Illumina 5-Base chemistry directly converts only 5mC to T in a simple, single step, which is nondamaging to DNA and retains library complexity.

**What benefits does this method have over bisulfite conversion?**

* Since 5-Base conversion is enzymatic, not chemical, the DNA is not damaged or degraded.
* This allows for methylation and variant calling in the same assay.
* With this method, the base diversity of the library is also preserved.
* The workflow is simpler and shorter than most on-market methylation-only products.

**How do whole-genome and target enrichment sequencing strategies for methylation studies differ?**

* Whole-genome sequencing covers the entire genome, while targeted enrichment sequencing focuses on select genomic regions. Both strategies can detect DNA methylation at single-base resolution.

**How complex is the 5-Base data analysis solution, given it provides dual insights?**

* The 5-Base bioinformatics solution does not require advanced expertise. It offers highly accurate variant and methylation detection. This is a simple, powerful, and easy-to-use multiomic analysis solution.

**Are there any limitations for CG-rich samples?**

* Illumina has not observed detection bias related to CG content in the human genome, either high or low.

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                              |
| :--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #9939), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000009939%20-%20Library%20Preparation%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://knowledge.illumina.com/library-preparation/general/library-preparation-general-faq-list/000009939.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.