> For the complete documentation index, see [llms.txt](https://knowledge.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://knowledge.illumina.com/instrumentation/miseq-ruo/instrumentation-miseq-ruo-reference_material-list/000001670.md).

# Specifications for the MiSeq

![](https://761066130-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGM9W2DuBTgEXv1ClCm8H%2Fuploads%2Fgit-blob-2133f29abef389c84f9394ca3a604206c2e61078%2Fimage1.png?alt=media\&token=d9def906-3bce-4171-8329-0295bd24bb25)

\* Total time includes cluster generation, sequencing, and base calling on a MiSeq System enabled with dual-surface scanning.\
**Note**: Output is measured in Gb (Gigabases) or Mb (Megabases).

**Reads Passing Filter**\
Install specifications based on Illumina PhiX control library at supported cluster densities (1000-1200 k/mm2 raw cluster density for v2 chemistry and 1200-1400 k/mm2 raw cluster density for v3 chemistry). Actual performance parameters may vary based on sample type, sample quality, and clusters passing filter.\
![](https://761066130-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGM9W2DuBTgEXv1ClCm8H%2Fuploads%2Fgit-blob-3726a04c977bd21a26a4bc1a4c2f7ca34be156ee%2Fimage2.png?alt=media\&token=ffefaa0a-8d49-48f5-9acd-cd0f6269e367)

**Quality Scores**\
A quality score (Q-score) is a prediction of the probability of an error in base calling. The percentage of bases ≥ Q30 is averaged across the entire run.\
![](https://761066130-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGM9W2DuBTgEXv1ClCm8H%2Fuploads%2Fgit-blob-dd68642d411da9056c8734d9ba69b8ba9bbb3a58%2Fimage3.png?alt=media\&token=7dcb8b95-51a5-4ce2-b34c-60f2b73ce7d7)

**Imaging**\
The number of tiles and surfaces for each kit type.

| **Kit Type**   | **Number of Tiles** | **Surfaces imaged** |
| -------------- | ------------------- | ------------------- |
| v2 Standard    | 14 tiles            | Dual surface        |
| v2 Micro       | 4 tiles             | Dual surface        |
| v2 Nano        | 2 tiles             | Single surface      |
| v3 Standard    | 19 tiles            | Dual surface        |
| v3 VeriSeq-PGS | 19 tiles            | Dual surface        |

This information is also available on the [Illumina MiSeq Specifications page](https://www.illumina.com/systems/sequencing-platforms/miseq/specifications.html), and a PDF version, here [MiSeq System Specifications Sheet](https://www.illumina.com/downloads/miseq-system-specification-sheet-m-gl-00006.html).

\
\
\ <br>

|                                                                                                                                                                                                                                                                                                                                                                        |
| :--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------: |
| *For any feedback or questions regarding this article (Illumina Knowledge Article #1670), contact Illumina Technical Support* [*techsupport@illumina.com*](mailto:techsupport@illumina.com?subject=Question%2FFeedback%20Regarding%20Illumina%20Knowledge%20Article%20#000001670%20-%20Instrumentation%20\&body=Dear%20Illumina%20Technical%20Support,%0D%0A%0D%0A)*.* |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://knowledge.illumina.com/instrumentation/miseq-ruo/instrumentation-miseq-ruo-reference_material-list/000001670.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.